Safety System

Process Unit Shutdown and Critical Control

– Safety Integrity Level (SIL) 1/2/3 Controller design, programming, and integration
– SIL rated instrument systems
– Critical alarming
– Redundant Infrastructure Design

Machinery Shutdown and Control

– Safety Integrity Level (SIL) 1/2/3 system design, programming, and integration
– Turbo-machinery control and surge protection
– Experience with multiple surge control systems including Triconex, Compressor Controls Corporation (CCC), and Trisen

Machinery Shutdown and Control

– Safety Integrity Level (SIL) 1/2/3 system design, programming, and integration
– Turbo-machinery control and surge protection
– Experience with multiple surge control systems including Triconex, Compressor Controls Corporation (CCC), and Trisen

Xenon Safety Controller

Xenon’s Safety System sets the standard for universal compatibility and flexibility for equipment and safety monitoring solutions. With an intuitive touch screen interface for easy programming and monitoring, Xenon’s Safety Controller merges form and function. Expandable up to 128 sensors, the Xenon Safety controller is ideal for new installations or as a retrofit to existing infrastructure.

Features:

  • Fully configurable from the 10” touch screen interface
    DSC_0199
  • Remote accessibility via built-in web interface
  • Local system configuration backup via USB drive for quick recovery in the event of equipment failure or for multiple system installation
  • On-board memory card for data storage / historization
  • Integrated alarm horn and lights
  • Individual sensor configuration for ranges and alarming (high/low/time delay)
  • Customizable sensor and alarm groups
  • Link relay outputs to sensor or common trouble alarms
  • Individual sensor bypass for online testing
  • Wireless option available for remote monitoring (4G or Ethernet)

Applications: 

  •  Process analyzer shelter monitoring
  • CEMS Shelter safety
  • Process unit safety monitoring
  • Hazardous gas monitoring
  • Equipment health monitoring

Technical Specifications:

Display:DSC03248

  • 800×600 resolution with backlight
  • Touchscreen interface for monitoring and configuration

Input Power:

  • 24VDC, 85-264 VAC, 90-350VDC

Output Power:

  • 12-48VDC, selectable

Enclosure Options:

  • 19” rack mount
  • NEMA 4X, NEMA 12
  • Stainless steel, Fiberglass, Mild Steel

Communications Protocols:

  • MODBUS TCP
  • MODBUS RTU (RS-232/485)
  • Profibus
  • OPC
  • Ethernet/IP

Inputs:

  • MODBUS RTU
  • 4-20mA DC Analog
  • Bridge Sensor Inputs

Certifications:

  • Class I, Div II Grp BCD (Hazardous Location Model)
  • Class I Div I, with Purge

Outputs:

  • 5A DC/AC Relay (Fail safe/non-failsafe,

Latching/non-latching)

  • Up to 12 digital outputs
  • Up to 8 Digital Outputs, 4 Relay Outputs
  • Up to 4 analog outputs to mirror sensor inputs

Operating Temperature:

  • -20C to +45C

Options:

  • External light / horn
  • Z or Y Purge (Div I)
  • 4G/Ethernet Wireless

Brochure
Xenon Safety Controller Brochure

Brochure
Xenon Safety Controller Brochure

Contact Us